XL Eagle Send us your price
Ohio bid · open for prices

Agilent GC/MS Systems and Installation

GC systems: Two Agilent 8890B units: one helium configuration with helium conservation module and one hydrogen configuration. Both require multimode inlets with N2 cooling, MSD interfaces, factory plumbing, and exhaust deflectors.

Due
December 3, 2026
14 days left
Location
Ohio
Posted on
ohiobuys.ohio.gov
Notice ID
SRC0000042763

Please quote two complete Agilent GC/MS systems, including delivery to ACF Receiving in Columbus, Ohio, installation, configuration, and startup.

  • Brand: Agilent only, with manufacturer authorization confirmed.
  • GC systems: Two Agilent 8890B units, one helium configuration with helium conservation module and one hydrogen configuration, both with multimode inlets with N2 cooling, MSD interfaces, factory plumbing, and exhaust deflectors.
  • Mass spectrometers: Two Agilent 5977C Inert Plus MSD Turbo EI bundles set up for each carrier gas, with HydroInert requirements, oil-free diaphragm pumps, and 24-inch monitors.
  • Autosamplers: Two 7693A autoinjectors with turrets, posts, 10 µL syringes and solvent bottles, plus two installed 150-vial tray systems.
  • Software: Two MassHunter workstations with MassHunter and ChemStation data analysis, one year of updates and phone support, one extra 10-license MassHunter data analysis package, and two latest-version NIST MS library upgrades.
  • Support: Three-year enhanced extended warranty for both systems and three days of onsite method consulting for up to four participants, with all labor, documentation, and freight included.

Please confirm availability and send your quote by December 3, 2026.

What it takes to win this job

Past winners charged about $110,000 per gc/ms system. This job is 2 gc/ms systems, so about $220,000.

Rough guideBased on 21 past awards for the same work, each divided down to one gc/ms system. Past prices were far apart, so check this against your own costs.

To win it, you need

  • Brand authorization: Supply Agilent only and confirm manufacturer authorization.
  • Required systems: Provide two 8890B systems with 5977C Inert Plus MSD Turbo EI bundles, one configured for helium and one for hydrogen.
  • Included support: Include three-year enhanced extended warranties and three days of onsite consulting for up to four participants.
  • Quote contents: Itemize the quote, include all labor, documentation and freight, and confirm availability and delivery lead time.
  • Quote deadline: The quote request says December 1, 2026; the posting lists December 3, 2026.

Past awards for the same work

Who wonTotalSizePer unitDate
Government Scientific Source INCGC/MS systems with installation and training $314,5552 gc/ms systems$157,278Oct 2026
Agilent Technologies INCGC/MS system for forensic research $128,5841 gc/ms system$128,584Sep 2026
Agilent Technologies INCGC/MS system $95,8651 gc/ms system$95,865Sep 2026
Agilent Technologies INCTriple quadrupole GC/MS system with installation $215,7491 gc/ms system$215,749Aug 2026
Government Scientific Source INCGC/MS system for food safety research $229,5481 gc/ms system$229,548Aug 2026
Agilent Technologies INCGC/MS systems $217,3082 gc/ms systems$108,654Jun 2026

Past prices come from public federal award records on USAspending.gov. State and local buyers do not post theirs in one place, so these are federal buys of the same work. Your price still has to cover your own costs.

The original documents

Deadline: December 3, 2026

See the original on ohiobuys.ohio.gov

Bidding it yourself? Get the full package and submit on ohiobuys.ohio.gov before December 3, 2026.

What they need

  • Mass spectrometersTwo Agilent 5977C Inert Plus MSD Turbo EI bundles, configured for the respective carrier gases, including HydroInert requirements, oil-free diaphragm pumps, and 24-inch monitors.
  • AutosamplersTwo 7693A autoinjectors with turrets, mounting and parking posts, 10 µL syringes, and solvent bottles; two 150-vial tray systems, installed.
  • SoftwareTwo MassHunter workstations with MassHunter and ChemStation data analysis, installation, introduction, and one year of updates/phone support; one additional 10-license MassHunter data analysis package; two latest-version NIST MS library upgrades.
  • Columns and accessoriesTwo each of 19091S-577UI HP-5MS Ultra Inert columns (20 m × 0.18 mm × 0.18 µm), G3440-81013 MSD nuts, G3440-81011 column nuts, and G3440-80217 pre-swaging tools; two 10-packs of 5181-3323 ferrules; one G7078-20909 9 mm HydroInert extractor lens; one each of installation kits 19199S and 19199M.
  • SupportThree-year enhanced extended warranty for both systems and three days of onsite method/application consulting for up to four participants. Include all labor, documentation, and freight.