Term: Two years, including 24/7 fire alarm monitoring and quarterly remote monitoring equipment inspections.
Due
November 16, 2026
8 days left
Location
Maryland
Posted on
Maryland eMMA
Notice ID
BPM059356
Please quote two years of fire safety system monitoring, inspections, preventive maintenance, and repairs at Deer’s Head Hospital Center, 351 Deers Head Hospital Road, Salisbury, MD 21801.
Monitoring: Fire alarm monitoring 24 hours a day, seven days a week, with quarterly inspections of remote monitoring equipment.
Alarm testing: Annual testing of 1 fire alarm control panel, 8 annunciators, 1 pre-action panel, 60 pull stations, 12 heat detectors, 171 smoke detectors, 18 duct detectors, 39 door holders, 141 sound and light alarm devices, and 4 elevator emergency control functions; sensitivity testing of 171 smoke detectors every two years.
Recurring tests: Annual, twice-yearly, and quarterly testing of 6 backup batteries; quarterly testing of 11 waterflow and 15 tamper switches; twice-yearly ANSUL kitchen hood connection and mechanical inspections.
Suppression systems: Inspections and testing under NFPA 25 for sprinklers, fire pump, jockey pump, backflow preventer, and pre-action system, including annual flow tests and quarterly checks of 6 check valves, 8 gauges, and 8 control valves.
Technicians: NICET II technicians and emergency response within 1 hour, available 24 hours a day, seven days a week.
Reports: Building Reports inspection reports within 7 working days.
Please confirm availability and send your quote by November 16, 2026.
The original documents
Deadline: November 16, 2026
See the original on emma.maryland.gov
Bidding it yourself? Get the full package and submit on Maryland eMMA before November 16, 2026.
What they need
Fire alarm systemsAnnual testing of 1 fire alarm control panel, 8 annunciators, 1 pre-action panel, 60 pull stations, 12 heat detectors, 171 smoke detectors, 18 duct detectors, 39 door holders, 141 audible/visual devices, and 4 elevator emergency control functions; biennial sensitivity testing of 171 smoke detectors.
Recurring testsAnnual, semiannual, and quarterly testing of 6 backup batteries; quarterly testing of 11 waterflow and 15 tamper switches; semiannual ANSUL kitchen hood interface and mechanical inspections.
Suppression systemsNFPA 25 inspections and testing of sprinklers, fire pump, jockey pump, backflow preventer, and pre-action system, including annual flow tests and quarterly checks of 6 check valves, 8 gauges, and 8 control valves.
Service requirementsNICET II technicians, 24/7 emergency response within 1 hour, and Building Reports inspection reports within 7 working days.
PricingInclude all labor, materials, equipment, and travel; provide monitoring and inspection pricing plus regular and overtime hourly rates for repair technicians and helpers.