XL Eagle Send us your price
Federal government job · open for prices

FY27 annual fire detection, annual fire suppression & semi annual ansul kitchen hood inspections, USP atwater

Due
November 13, 2026
5 days left
Location
Atwater, CA
California
Buyer
Federal Prison System / Bureau of Prisons
Usp Atwater · Department of Justice
NAICS
561621
Security Systems Services (except Locksmiths)
Notice ID
15B61827Q00000002
Posted November 5, 2026

Please quote one annual fire detection system test, one annual fire sprinkler and riser test, and two kitchen hood fire system maintenance visits at USP Atwater, 1 Federal Way, Atwater, CA 95301.

  • Alarm testing: Test approximately 15 Simplex alarm panels, 35 alarm display panels, 540 smoke detectors, 240 pull stations, 45 heat detectors, 140 duct detectors, 60 flow switches, and 70 tamper switches to NFPA 72.
  • Sprinkler testing: Test approximately 53 wet risers, 3 dry risers, and 2 electric fire pumps to NFPA 25.
  • Hood maintenance: Inspect and maintain approximately 9 ANSUL systems twice yearly across two kitchens and one chemical/battery storage locker at the penitentiary and Federal Prison Camp, including replacement of fusible links and spray nozzles, to NFPA 96.
  • Permits: Obtain permits if required.
  • Security: All workers must pass an NCIC background check and follow prison security rules, including tool searches and inventories and restrictions on personal items and electronics.

Please confirm availability and send your quote by November 13, 2026.

The original documents

Deadline: November 13, 2026

  • Attachment 1
  • Attachment 2
  • Attachment 3
  • Attachment 4
  • Attachment 5

See the original on sam.gov

Bidding it yourself? Search notice 15B61827Q00000002 on SAM.gov and submit before November 13, 2026. You need an active SAM.gov registration.

What they need

The Federal Bureau of Prisons (FBOP), United States Penitentiary in Atwater, California intends to make a single award to a qualified responsible entity to perform (1) Annual Fire Detection System testing, (1) Annual Fire Sprinkler/Riser Testing, and (2) Semi-Annual ANSUL Kitchen Hood Fire System Maintenance. They are located at United States Penitentiary Atwater, 1 Federal Way, Atwater, CA 95301. It is the Contractor�s responsibility to obtain permitting, should it be required.

Annual Fire Detection System Alarm & Pull Station Testing: Inspection and testing of approximately 15 Simplex fire alarm panels, 35 annunciators, 540 smoke heads, 240 pull stations, 45 heat detectors, 140 duct detectors, 60 flow switches, and 70 tamper switches in accordance with NFPA 72. Annual Fire Sprinkler and Riser Testing: Comprehensive testing of approximately 53 wet risers, 3 dry risers, and 2 electric fire pumps in accordance with NFPA 25. Semi-Annual ANSUL Kitchen Hood Maintenance: Semi-annual inspection and maintenance of approximately 9 kitchen hood fire suppression systems located across two (2) kitchens and one (1) chemical/battery storage locker at the USP and Federal Prison Camp, to include replacing fusible links and spray nozzles in accordance with NFPA 96 Institutional Security Requirements (USP Atwater) The performance of this contract takes place within a high-security federal penit

Similar open contracts

More like this: Security Services contracts in California