This bid is for microwave system replacement consulting at 100 Court Plaza, 166 Reservoir Road, and 1599 Spivey Mountain Road in Asheville, North Carolina.
Due
January 7, 2027
47 days left
Location
Asheville, NC
North Carolina
Posted on
evp.nc.gov
Notice ID
298-FY27-ITS-RFP-MicrowaveConsulting
Please quote microwave radio system replacement consulting for sites at 100 Court Plaza, 166 Reservoir Road, and 1599 Spivey Mountain Road in Asheville, North Carolina.
System: Two 11.2 GHz P25 radio backhaul paths of 0.80 and 6.08 miles, at least 100 Mbps capacity (150 Mbps or more preferred), compatible with future Nokia MPLS Layer 3.
Assessment: Site surveys, review of documentation and path studies, a theoretical path study, waveguide reuse recommendations, a conceptual design, and estimated replacement costs.
Selection: Write technical specifications and evaluation criteria, evaluate installer proposals, negotiate pricing, and review warranty and maintenance options.
Oversight: On-site installation and cutover oversight, testing and acceptance, licensing support, documentation review, and punch-list resolution. No tower climbing required.
Schedule: 6 weeks for assessment, 4 weeks for specifications, 6 weeks for vendor selection, and 24 weeks for installation oversight, with cutover complete by November 18, 2027.
Please confirm availability and send your quote by January 7, 2027.
The original documents
Deadline: January 7, 2027
See the original on evp.nc.gov
Bidding it yourself? Get the full package and submit on evp.nc.gov before January 7, 2027.
What they need
SystemTwo 11.2 GHz P25 radio backhaul paths spanning 0.80 and 6.08 miles; minimum 100 Mbps capacity, preferably 150 Mbps or more, with future Nokia MPLS Layer 3 compatibility.
AssessmentSite surveys, documentation and path study review, theoretical path study, waveguide reuse recommendations, conceptual design, and estimated replacement costs.
Selection supportDevelop technical specifications and evaluation criteria, evaluate installer proposals, negotiate pricing, and review warranty and maintenance options.
Deployment oversightOn-site installation and cutover oversight, testing and acceptance, licensing support, documentation review, and punch-list resolution. No tower climbing required.