The original documents
Deadline: January 5, 2027
See the original on www.nyscr.ny.gov
Bidding it yourself? Get the full package and submit on nyscr.ny.gov before January 5, 2027.
What they need
- Test kitsActivated charcoal open-faced or diffusion barrier canisters for 48-hour to 7-day testing, with a minimum detectable concentration of 0.5 pCi/L and illustrated English and professionally reviewed Spanish instructions.
- LaboratoryMaintain New York ELAP certification for activated charcoal radon-in-air testing and perform gamma spectroscopy analysis in-house.
- TurnaroundShip kits within 14 calendar days of orders and provide written user results plus printed and electronic program reports within 14 calendar days of receiving returned detectors.
- Quality assuranceInclude quarterly testing in an NRPP- or NRSB-approved radon chamber.
- PricingItemize detector unit cost; shipping for 1, 2–5, 6–49, 50–200, and 201+ units; and per-unit return Business Reply Mail, analysis, and reporting. Include packaging and postage.
Get new New York bids by email
Save a search and we email you when a matching bid is posted. Free. Unsubscribe anytime.
More New York bids → · All states →