Scope: Field-measure five openings, remove and dispose of existing doors, and supply and install three pairs and two single doors, including required hardware.
Due
December 2, 2026
24 days left
Location
Maryland
Posted on
Maryland eMMA
Notice ID
BPM059623
Please quote replacement of three pairs and two single doors at Conococheague WWTP, Control Building, 16232 Elliott Parkway, Williamsport, MD 21795.
Services: Measure five openings, remove and dispose of existing doors, and supply and install replacements with required hardware.
Main entrance: Ceco LP insulated 18-gauge galvanized steel doors with 6” x 30” safety-glass windows and a new Ceco SU 16-gauge galvanized welded frame, 5-3/4” deep, with masonry anchors, or equal.
Lab entrance: Matching steel doors with safety-glass windows; repair, paint and reuse the existing frame and provide protective frame covers.
Other doors: Insulated fiberglass doors, Tiger Door Heavy Duty Series by Phoenix Door Systems or equal; reuse specified frames, hinges and the exterior over-door frame, and repair the rear lab frame.
Hardware: Provide the specified exit devices, locks, closers, protective plates, thresholds and weather seals; steel door pairs also need new stainless steel hinges.
Schedule: Complete within 90 calendar days of award and provide at least a 12-month warranty.
Please confirm availability and send your quote by December 2, 2026.
The original documents
Deadline: December 2, 2026
See the original on emma.maryland.gov
Bidding it yourself? Get the full package and submit on Maryland eMMA before December 2, 2026.
What they need
Main entrancePair of Ceco LP insulated 18-gauge galvanized hollow metal doors with 6” x 30” safety-glass lites; new Ceco SU 16-gauge galvanized, 5-3/4” welded transom/sidelite frame with masonry anchors, or equal.
Lab entranceMatching hollow metal door pair with safety-glass lites; reuse existing transom frame, rehabilitate and paint frame to match, and provide frame spats.
Chemical storageOne exterior pair and one interior single insulated FRP door, Tiger Door Heavy Duty Series by Phoenix Door Systems or equal. Reuse stainless steel frames and hinges, plus exterior transom.
Rear lab entranceOne matching insulated FRP single door; rehabilitate and reuse existing hollow metal frame and hinges.
HardwareDoor pairs require vertical-rod exit devices, rim cylinders, hold-open closers, kickplates, thresholds, sweeps and weatherstripping; hollow metal pairs also require new stainless steel hinges. Interior FRP single requires a lockset and hold-open closer; rear FRP single requires a rim exit device, cylinder, closer, kickplate, threshold, sweep and weatherstripping.
Pricing and scheduleInclude all materials, labor, equipment, delivery, disposal and applicable fees in a lump sum. Complete within 90 calendar days of award and provide a minimum 12-month warranty.