91st Cyber Operations Center - Progressive Design-Build Other Transaction Agreement
The government needs progressive design-build services for a roughly 42,000-square-foot, multi-story 91st Cyber Operations Center at Joint Base San Antonio, Lackland Air Force Base, Texas.
Commercial and Institutional Building Construction
Notice ID
W9126G27QA008
Posted November 17, 2026
Please quote design and construction of an approximately 42,000-square-foot, multi-story 91st Cyber Operations Center at Joint Base San Antonio, Lackland Air Force Base, Texas.
Facility: Approximately 42,000-square-foot, multi-story cyber operations facility built to security and technical standards for a mission-critical cyber environment.
Delivery model: Progressive Design-Build under an Other Transaction Agreement.
Phase 1: Design and pre-construction services: refine requirements, advance the design, validate cost and schedule, and support the Phase 2 scope.
Phase 2: Possible construction packages, 2A site/civil and early work and 2B building construction, added later if approved and funded. The Government is not obligated to proceed.
Selection: Two steps: a White Paper, then invitation-only evaluation pitch meetings.
Submission: White Paper must address all requirements in Attachment 1.
Please confirm availability and send your quote by November 18, 2026.
The original documents
Deadline: November 18, 2026
Attachment 1PDF · 6 pages
Attachment 2PDF · 400 pages
Attachment 3PDF · 13 pages
Attachment 4PDF · 4 pages
Attachment 5PDF · 50 pages
See the original on sam.gov
Bidding it yourself? Search notice W9126G27QA008 on SAM.gov and submit before November 18, 2026. You need an active SAM.gov registration.
What they need
Project scopeDesign and build a multi-story cyber operations facility of about 42,000 square feet for the Air Combat Command 91st Cyber Operations Squadron.
Delivery methodProgressive Design-Build under an Other Transaction Agreement (10 U.S.C. 2808a), run by USACE Fort Worth District for the Department of the Air Force.
Two project phasesPhase 1 is design and pre-construction services; Phase 2 is construction (2A site/civil and early work, 2B building construction), authorized by amendment only if the Government chooses to proceed and funds are available.
Standards to meetThe facility must meet applicable security and technical standards for a mission-critical cyber operations environment, as detailed in Attachment 2, Project Requirements Document.
Selection processTwo steps: a White Paper addressing all of Attachment 1, then invitation-only Evaluation Pitch Meetings.
Key deadlinesQuestions are due through ProjNet by 11 November 2026; White Papers are due 17 November 2026 at 1400 Central Time by email with the subject line "White Paper for 91st Cyber Operations Center".
What you have to submit
Pulled from the 5 solicitation documents (473 pages). Each item links to the page it came from. Check the originals and any amendments before you bid.
1How and where to submit
Contractors must submit to the Security Office via the Contracting Officer, an access list of all personnel who will be working on the contract jobSource: Attachment 2, page 25
Contractor vehicles requiring admittance into the CIA must be submitted to the Puget Sound Naval Shipyard Security Office via a CIA Vehicle Pass Request (PSNS & IMF 5530/25)Source: Attachment 2, page 39
This includes briefcases, handbags, tool chests, boxes, sealed packages, and personal articlesSource: Attachment 2, page 44
Electronic Invoices Submit invoices electronically via e-mail or computer discSource: Attachment 2, page 53
2Deadline
Army Corps of Engineers (USACE), Fort Worth District Response Deadline: 19 November 2026 at 1400 Central Time ISSUE DATE: 17 NOV 2026 AMENDMENT NOSource: Attachment 1, page 1
Performance Bond The Performance Bond [must remain effective throughout the construction and warranty period] [_____]Source: Attachment 2, page 389
7Licenses you need
INFORMATION ONLY SUBMITTALS Submittals without a "G" designation must be certified by the QC manager and submitted to the ContractingAgreements Officer for information-onlySource: Attachment 2, page 99
The report must be stamped by the licensed corrosion engineer or NACE specialist with the first design submissionSource: Attachment 2, page 159
Contractor's Site Safety and Health Officer (SSHO) must collect and maintain the certified EMR ratings for all subcontractors on the project and make them available to the Government at the Government's requestSource: Attachment 2, page 190
Contractor's Site Safety and Health Officer (SSHO) must collect and maintain self-certified OSHA DART rates for all subcontractors on the project and make them available to the Government at the Government's requestSource: Attachment 2, page 191
Third Party Certification of Floating Cranes and Barge-Mounted Mobile Cranes Floating cranes and barge-mounted mobile cranes used to perform work under the terms of this Contract must be certified in accordance with 29 CFR 1919 by an OSHA accredited person prior to submitting the required Lift PlanSource: Attachment 2, page 201
8Pricing format
Non-procurement activities Original Durations (OD) are not to exceed 20 workdays or 30 calendar daysSource: Attachment 2, page 69
The approved Preliminary Project Schedule will be used for payment purposes not to exceed 90 calendar days after NTPSource: Attachment 2, page 76
Completely cost load the Preliminary Project Schedule to balance the contract award CLINS shown on the Price ScheduleSource: Attachment 2, page 76
Set up cost loading using a single lump sum non-labor resourceSource: Attachment 2, page 83
Other recent awards in this industry in Texas
Recent federal contract awards in the same industry in Texas, from USAspending.gov. These are other jobs, not the same work as this one. Do not use them as a price guide for this job.
Who won
Amount
Buyer
Date
Wright Bros LLCThe project renovates the existing pistol range facility, building D, and converts IT to office and storage sp…