Interior: Closed-cell spray foam insulation, painted plywood walls and ceilings, industrial epoxy flooring, and blocking for wall-mounted equipment. Specify insulation thickness and R-value.
HVAC: Mini-split heat-pump heating and cooling sized for West Texas conditions; two zones if needed for balanced coverage. Include manufacturer, model, and BTU capacity.
Doors and windows: Per office, one 36 × 79-inch steel personnel door with closer and keypad lock, plus two 4 × 4-foot insulated, tinted, reflective windows.
Electrical and lighting: 100-amp outdoor panel, dedicated equipment circuits, eight interior duplex receptacle locations, a four-gang workstation arrangement, display and rack power, two exterior receptacles, dimmable interior LED lighting, and five exterior floodlights per office.
Workspace: Two-person workstation area, one approximately 10-foot laminate-finished fold-down table with folding legs, and reinforced mounting locations with power/data provisions for two 65-inch displays per office.
Data: CAT6 cabling with at least four ports, wall-mounted network rack, indoor and outdoor PoE access-point cabling, weatherproof exterior network box, and spare-capacity communications entry point per office.
Safety and warranty: Mounted 5-pound ABC extinguisher, illuminated EXIT sign with emergency lighting, and minimum five-year conversion/workmanship warranty.
The basics